Volusia Christmas Lights

LED vs Incandescent Christmas Lights for a Florida Roofline

On a 150-foot roofline, 150 incandescent C9s draw about 1,050 watts, or 8.75 amps, and cost about $28.50 a month to run. The site's published LED example draws 50 watts, under half an amp, for about $1.36. Over five seasons that is roughly $142 against $7, with far less heat on the eave.

Bulb size and socket are settled on C9 vs C7 Christmas lights. This page is about the other choice inside the bulb: a glowing filament or a light-emitting diode. It covers what each one draws from the outlet, how hot it runs, how each kind fails, and what the difference adds up to after several Decembers. The load side, meaning how many runs one circuit can carry, has its own page on power and circuits.

What each technology does with a watt

An incandescent bulb makes light by heating a thin filament until it glows. Most of the electricity becomes heat rather than light, which is why an old C9 is warm to the touch after an hour on the eave. An LED makes light from a semiconductor chip. It needs a small fraction of the power for a similar look from the street, and the bulb stays close to air temperature.

For a homeowner that difference shows up in three places: the electric bill, the load on the outlet, and how the strand behaves when something goes wrong. The table puts the first two side by side on one roofline.

One 150-foot roofline in each technology. Wattages are the figures this site publishes; amps are watts divided by 120 volts. Arithmetic, not a utility quote.
On a 150-foot rooflineDrawAmps at 120 voltsAbout per month, 6 hours a night
150 incandescent C9s at 7 watts, 12-inch spacingAbout 1,050 wattsAbout 8.75$28.50
120 incandescent C9s at 7 watts, 15-inch spacingAbout 840 wattsAbout 7.0$22.80
LED run, the site's published 50-watt example50 wattsAbout 0.42$1.36

The bill across several seasons

One month of difference is about $27. That sounds small until the same lights go up every year. The figures below stack the site's monthly numbers, thirty nights at the Florida residential average of 15.1 cents per kWh, across one, three, five, and ten seasons. The twelve-hour column is for displays left on a long timer setting, which doubles everything.

Cumulative electricity for one 150-foot roofline, thirty nights a season at 15.1 cents per kWh. Purchase prices excluded.
SeasonsIncandescent C9, 6 hoursLED example, 6 hoursIncandescent C9, 12 hoursLED example, 12 hours
1About $28.50About $1.36About $57.10About $2.72
3About $85.50About $4.08About $171.30About $8.16
5About $142.50About $6.80About $285.50About $13.60
10About $285.00About $13.60About $571.00About $27.20

Bulb purchase prices are not in the table, because this site does not publish retail prices for either kind. What it shows is the running cost alone: ten seasons of an incandescent roofline at six hours a night costs about $285 in electricity, and the LED example costs about $14. Read the wattage printed on the box of any product you are pricing and scale from there.

Heat on the eave and on the outlet

Over a kilowatt of incandescent bulbs is a kilowatt of mostly heat spread along the fascia, the gutter, and whatever plastic clips hold the wire. It is also 8.75 amps on one circuit, more than half of what a common 15-amp household circuit is rated to carry, before anything else in the house shares it. That is the practical reason incandescent displays trip breakers and LED displays rarely do.

The LED run in the table pulls under half an amp. The bulbs stay cool enough to handle, the clips are not baking, and a long roofline can share an outlet with the palm wraps without crowding the circuit. How to add up a whole display against the circuit it plugs into is worked through on power and circuits.

How each kind fails

An incandescent bulb fails when its filament breaks. On C9 socket wire, where each bulb has its own socket on the run, that leaves one dark spot, and a new bulb screws in. On many retail mini-light sets the bulbs are wired in series sections, so one loose or missing bulb can take a whole section dark until it is found.

An LED rarely burns out in the same way. In Florida the parts that go first are the ones around the diode: the connection where a plug meets a socket, the seal around the base, and plastic that sits in sun and humidity. Salt air east of the Halifax River makes that worse. That is why the construction of the strand matters as much as the technology, which is the subject of commercial vs retail Christmas lights.

Where incandescent still gets chosen

The case for incandescent is the look. A filament has a soft, slightly amber glow that some people associate with older displays, and a homeowner who wants exactly that may accept the bill. Warm white LEDs are made to come close to it, and the difference between warm and cooler LED whites is its own page: warm white vs pure white.

For a seasonal roofline that someone else maintains, the case is weaker. The seasonal packages on this site use commercial C9 LEDs, which screw into the same C9 socket wire an incandescent bulb would. Switching technology does not mean new wiring, only new bulbs.

Keep going in the materials guide

Common questions

For a Florida roofline, LED. On the site's published figures a 150-foot incandescent C9 run costs about $28.50 a month to run against about $1.36 for the LED example, and it puts about 8.75 amps on one circuit against under half an amp. Choose incandescent only if the soft filament glow is the look you want and you accept the bill.

Get a free design quote

Tell us about the property and we will send a price for the full season, lights included.

Get a Free Design Quote