LED vs Incandescent Christmas Lights for a Florida Roofline
On a 150-foot roofline, 150 incandescent C9s draw about 1,050 watts, or 8.75 amps, and cost about $28.50 a month to run. The site's published LED example draws 50 watts, under half an amp, for about $1.36. Over five seasons that is roughly $142 against $7, with far less heat on the eave.
Bulb size and socket are settled on C9 vs C7 Christmas lights. This page is about the other choice inside the bulb: a glowing filament or a light-emitting diode. It covers what each one draws from the outlet, how hot it runs, how each kind fails, and what the difference adds up to after several Decembers. The load side, meaning how many runs one circuit can carry, has its own page on power and circuits.
What each technology does with a watt
An incandescent bulb makes light by heating a thin filament until it glows. Most of the electricity becomes heat rather than light, which is why an old C9 is warm to the touch after an hour on the eave. An LED makes light from a semiconductor chip. It needs a small fraction of the power for a similar look from the street, and the bulb stays close to air temperature.
For a homeowner that difference shows up in three places: the electric bill, the load on the outlet, and how the strand behaves when something goes wrong. The table puts the first two side by side on one roofline.
| On a 150-foot roofline | Draw | Amps at 120 volts | About per month, 6 hours a night |
|---|---|---|---|
| 150 incandescent C9s at 7 watts, 12-inch spacing | About 1,050 watts | About 8.75 | $28.50 |
| 120 incandescent C9s at 7 watts, 15-inch spacing | About 840 watts | About 7.0 | $22.80 |
| LED run, the site's published 50-watt example | 50 watts | About 0.42 | $1.36 |
The bill across several seasons
One month of difference is about $27. That sounds small until the same lights go up every year. The figures below stack the site's monthly numbers, thirty nights at the Florida residential average of 15.1 cents per kWh, across one, three, five, and ten seasons. The twelve-hour column is for displays left on a long timer setting, which doubles everything.
| Seasons | Incandescent C9, 6 hours | LED example, 6 hours | Incandescent C9, 12 hours | LED example, 12 hours |
|---|---|---|---|---|
| 1 | About $28.50 | About $1.36 | About $57.10 | About $2.72 |
| 3 | About $85.50 | About $4.08 | About $171.30 | About $8.16 |
| 5 | About $142.50 | About $6.80 | About $285.50 | About $13.60 |
| 10 | About $285.00 | About $13.60 | About $571.00 | About $27.20 |
Bulb purchase prices are not in the table, because this site does not publish retail prices for either kind. What it shows is the running cost alone: ten seasons of an incandescent roofline at six hours a night costs about $285 in electricity, and the LED example costs about $14. Read the wattage printed on the box of any product you are pricing and scale from there.
Heat on the eave and on the outlet
Over a kilowatt of incandescent bulbs is a kilowatt of mostly heat spread along the fascia, the gutter, and whatever plastic clips hold the wire. It is also 8.75 amps on one circuit, more than half of what a common 15-amp household circuit is rated to carry, before anything else in the house shares it. That is the practical reason incandescent displays trip breakers and LED displays rarely do.
The LED run in the table pulls under half an amp. The bulbs stay cool enough to handle, the clips are not baking, and a long roofline can share an outlet with the palm wraps without crowding the circuit. How to add up a whole display against the circuit it plugs into is worked through on power and circuits.
How each kind fails
An incandescent bulb fails when its filament breaks. On C9 socket wire, where each bulb has its own socket on the run, that leaves one dark spot, and a new bulb screws in. On many retail mini-light sets the bulbs are wired in series sections, so one loose or missing bulb can take a whole section dark until it is found.
An LED rarely burns out in the same way. In Florida the parts that go first are the ones around the diode: the connection where a plug meets a socket, the seal around the base, and plastic that sits in sun and humidity. Salt air east of the Halifax River makes that worse. That is why the construction of the strand matters as much as the technology, which is the subject of commercial vs retail Christmas lights.
Where incandescent still gets chosen
The case for incandescent is the look. A filament has a soft, slightly amber glow that some people associate with older displays, and a homeowner who wants exactly that may accept the bill. Warm white LEDs are made to come close to it, and the difference between warm and cooler LED whites is its own page: warm white vs pure white.
For a seasonal roofline that someone else maintains, the case is weaker. The seasonal packages on this site use commercial C9 LEDs, which screw into the same C9 socket wire an incandescent bulb would. Switching technology does not mean new wiring, only new bulbs.
Keep going in the materials guide
- Christmas light materials for Florida homes
Bulb, wire, clip, and timer: the four parts this choice sits inside.
- C9 vs C7 Christmas lights for Florida homes
The size decision, made before the technology one.
- Christmas light power and circuits
How many runs one outlet carries, worked in watts and amps.
Common questions
For a Florida roofline, LED. On the site's published figures a 150-foot incandescent C9 run costs about $28.50 a month to run against about $1.36 for the LED example, and it puts about 8.75 amps on one circuit against under half an amp. Choose incandescent only if the soft filament glow is the look you want and you accept the bill.
Outdoor-rated lights carrying a recognized safety listing mark, plugged into a GFCI-protected outdoor outlet, and connected no further than the strand's tag allows. Between the two technologies, LED is the lower-risk choice because it runs cool and draws a small fraction of the current, so it heats the eave less and is far less likely to overload a circuit.
No. LED Christmas lights plug into an ordinary outdoor outlet, and commercial C9 LED bulbs screw into the same C9 socket wire an incandescent bulb uses. Because they draw so little, they usually make the wiring question easier rather than harder. New outlets or hardwired power are a separate matter and are work for an electrician.
This site does not publish an hours rating, so check the box of the product you are buying. In Florida the diode is rarely what ends a strand. Plugs, socket seals, and plastic that sits in sun, humidity, and salt air fail first, which is why how the strand is built matters more than the bulb technology alone.
It depends on how the set is wired, not on the LED. On C9 socket wire each bulb has its own socket on the run, so one dead bulb leaves the rest lit. Many mini-light sets are wired in series sections, and on those a loose or missing bulb can darken its section until it is reseated or replaced.
LED draws far less power, runs cool, and adds little to the bill: about $1.36 a month for the site's 150-foot example against about $28.50 for incandescent C9s. Its weak points in Florida are plugs and seals rather than the diode. Incandescent offers the soft filament glow, but it runs hot, draws about 8.75 amps on that roofline, and fails bulb by bulb.
Get a free design quote
Tell us about the property and we will send a price for the full season, lights included.
Get a Free Design Quote